NOVAPLAST 800L

Fast curing CA adhesive for APTK/EPDM bonding

Chemische Basis

Aethylcyane acrylate

Inhalt

20g

Für folgende Materialien geeignet:

Aluminium

Beton

Chrom

Dachziegel

Fiberglas

Gips

Gipskarton

Glas

Holz

Keramik

Laminat

Metall

Polymere

Porzellan

PVC

Sperrholz

Stein

Ziegel

Zink

Beschreibung

  • Fast curing adhesive based on aethylcyane acrylate
  • Extremely quick curing
  • Extremely high tensile strength
  • Designed for bonding APTK/EPDM profiles in window construction
  • Excellent adhesion on rubber, metals, plastics, wood and ceramics
  • Bonding APTK/EPDM profiles in window construction
  • Quick bonding of rubber, metals, plastics, wood, ceramics
FEATURETECHNICAL VALUEINSPECTION CONDITIONS
Chemical basisAethylcyane acrylate
ColourColourless, transparent
ConsistencyMiddle fluid, 250 mPas
Operation stabilityApprox. 20-60 seconds
Curing time completeWithin 24 hours
Tensile strength (at 25°C)Approx. 13 N/mm²DIN 53283
Density~ 1,5 g/cm³23°C, 50% RAH
Hazardous Material Class:A III as per „Vbf“
Flashpoint:83°C
Softening point index:1.48 n20
Dielelectric Constant:3.4 (at 10kHz)
Specific Resistance:3.4 (at 10kHz)
VOC content<3% according to EU norm 999/13/EU
Shelf life12 months (stored dry, dark at 20°C)
Packaging20g bottle / 20 pcs. per box
MATERIALEIGNUNG
Aluminiumrecommended
Betonrecommended
Chromrecommended
Dachziegelrecommended
Fiberglasrecommended
Gipsrecommended
Gipskartonrecommended
Glasrecommended
Holzrecommended
Keramikrecommended
Laminatrecommended
Metallrecommended
Polymererecommended
Porzellanrecommended
PVCrecommended
Sperrholzrecommended
Steinrecommended
Ziegelrecommended
Zinkrecommended

This table is for guidance only and does not constitute a binding statement. In practice self-tests are to be carried out in advance. Further information can be obtained via our application technology.

Pretreatment:

Before applying the adhesive the user has to ensure that the materials in the area of contact (solid, liquid and gaseous) are compatible with the adhesive and do not damage or alter them. All adherent surfaces have to be clean, free from fat, dry and sustainable. Any contaminant such as release agents, preserving agents, grease, oil, dust, water, old adhesives or sealants and other substances which could affect adhesion, should be removed. Metal surfaces may need to be roughened. The humidity within workroom should range within 50-70%. The adhesion process is delayed when the humidity is too low.

Application information:

Apply adhesive in dots or thin lines, depending on scope of operation. The assemble parts are held together under pressure for approx. 20-60 seconds depending on their material. Because of the variety of possible influences while processing and application customer tests are required. Please observe the recommended shelf life which is printed on the packaging. The cured adhesive can only be removed mechanically. Because of the strong smell of the adhesive there needs to be good ventilation within the work rooms. Although the adhesive does not cause irritability of the skin, netting the skin should be avoided. Removing excess adhesive can be achieved with hand washing paste or with a hand washing stone. When working, the use of protective glasses is necessary! If the adhesive should spray into the eyes, perform an eye flush immediately with the appropriate infusion (boric water) and then visit a physician. In our experience no lasting damage has occurred.

Store away from sunlight, protected against moisture and heat. Shelf life is six months at a temperature of 20°C, refrigerated approximately 12 months and if stored in a freezer at almost unlimited. Before application the adhesive should be warmed to room temperature. If the products are stored and / or transported at higher temperatures / air humidity for longer periods (some weeks) / intensive sunlight, a diminution of durability or a change of material characteristics may arise.

Only for commercial users. Please observe material safety data sheet. For information about disposal please refer to material safety data sheet.

All information in this publication is based on our current technical knowledge and experiences. However, since conditions and methods of use and application of our products are beyond our control, we suggest you to test the product before final use. Information given in this technical data sheet is not to be seen as a warranty. Characteristics stated in this data sheet define characteristics of the article broadly and concluding. Suggestions of use are not to be taken as confirmation of the appropriateness for the recommended intended use. We reserve the right to improve the product adjusting it according to technical progress and new developments. We are at your disposal both for inquiries as well as specific application problems. If a governmental approval or clearance is necessary for the application of our products, the user is responsible for the obtainment of such. Our recommendations do not excuse the user from the obligation to take into consideration the possibility of infringement of third parties‘ rights.

More information about this product is available on request